Model 300S
|
Model 500S |
Model 600GSX-2 |
|
|
User Manual / EID Manual |
User Manual |
| Display |
1", 6 digit LCD
|
1", 6 digit LCD w/backlight |
1.5" Graphic LCD w/backlight |
| User Interface Language |
English |
English |
English, French (user switchable) |
| Computer Interface |
RS-232 w/optional RS-232, RS-422, RS-485
|
RS-232 w/ 2nd RS-232 or RS-485 |
| Alarm Detail |
N/A
|
One Logic Output |
One Logic Output |
| Remote Communication* |
Standard |
| Analog Output |
Available on Model 300IS (0 to 5VDC / 4 to 20mADC) |
N/A |
N/A |
| Electronic Identification** (EID) |
Optional |
Optional |
Standard |
| Weight Records |
1,600 / 3,200 with EID option |
1,350 / 12,800 with EID option |
10,000 |
| Weight Record Content |
Weight / Weight, Date & Time, EID with EID option |
Weight, Date & Time / Weight, Date & Time, EID with EID option |
Weight, Date & Time, EID, Visual ID |
| Unique Lots*** |
20 |
50 |
50 |
| Min/Max/Average (by Lot) |
Standard |
| Increments |
1, 2, 5, 10, w/decimal points
|
| Weighing Units |
lb / kg |
| Zero Tracking |
Programmable
|
| Average & Hold |
Standard
|
| Weight Triggered Alarm |
N/A |
Standard |
Standard |
| Gross/Net/Tare |
N/A |
Standard |
Standard |
| Calibration |
Field Adjustable
|
| Auto-Calibrate**** |
Standard |
| Supply Voltage (VDC)***** |
12 to 24
|
| Supply Current (mA), typical with 1 Load Cell |
100
|
200 |
300 |
| Load Cell Excitation (VDC) |
7.5
|
| Load Cell Capacity (350 ohm / 700 ohm) |
Up to 6 / 12
|
| Operating Temperature |
-5 F to 140 F / -20 C to 60 C
|
25 F to 140 F / -5 C to 60 C |
| Case Dimensions |
10"W x 7"H x 3.75"D / 25.4cm x 17.8cm x 9.5cm
|
| Approximate Shipping Weight |
7.5 lb / 3.4 kg
|
8.5 lb / 3.9 kg |
9 lb / 4.1 kg |
|
* Remote Communication allows control and interfacing to an external PC or similar device.
** Electronic Identification (EID) operation has been verified with Symbol® barcode readers (RS-232 output), Allflex® S-2000, Stick and Panel readers, Destron Technologies® 2001F-ISO, Syscan LiveTrack ISO Wand Reader as well as Y-Tex® Panel and Bluetooth® readers. Bluetooth readers require an additional adapter.
*** Lots are used to group weight records, e.g. by pen, truckload, etc.
**** Auto-Calibrate feature requires compatible load cells from Reliable Scale
*****115vac to 12VDC adapter included as standard; battery clips or cigarette lighter adapter available as options
Specifications subject to change without notice.
|